surescreen diagnostics pregnancy test instructions

The Surescreen Diagnostics Pregnancy Test is a reliable, FDA-approved, and CE-marked diagnostic tool designed for early pregnancy detection. It offers high accuracy and easy-to-use formats, ensuring quick results.

Overview

The Surescreen Diagnostics Pregnancy Test is a rapid, accurate, and user-friendly diagnostic tool designed for early pregnancy detection. Available in One-Step Test Strip and Midstream formats, it offers high sensitivity and convenience. Utilizing immunoassay technology, it detects hCG levels in urine with over 99% accuracy. CE Marked and FDA Approved, it ensures reliable results for home or professional use, providing peace of mind with clear and quick outcomes.

Importance of Following Instructions

Adhering to the Surescreen Diagnostics Pregnancy Test instructions ensures accurate and reliable results. Proper steps, such as timing, sample collection, and test handling, are crucial for detecting hCG levels effectively. Deviating from guidelines may lead to errors or invalid outcomes, emphasizing the need to follow each step carefully for precise and trustworthy pregnancy detection results every time.

Types of Surescreen Tests

The Surescreen Diagnostics offers two convenient test formats: the One-Step Test Strip for dipping and the Midstream Test in cassette format for easy, mess-free application.

One-Step Test Strip

The One-Step Test Strip is a user-friendly option designed for quick results. To use, dip the test strip vertically into a urine sample for 15 seconds. The strip uses immunoassay technology to detect hCG levels, providing accurate results as early as one day after a missed period. Results appear within 3 minutes, showing two lines for positive and one line for negative outcomes. This format is ideal for those who prefer a straightforward and time-efficient testing method, ensuring reliability and convenience with CE marking and FDA approval.

Midstream Test

The Surescreen Midstream Test is a convenient and hygienic option for detecting pregnancy. It involves placing the test stick in the urine stream, ensuring a clean sample. Results appear in minutes, with two lines indicating a positive result and one line for negative. This method is preferred for its ease of use and minimal mess, providing accurate and quick results with high sensitivity.

Preparing for the Test

Bring the test to room temperature (15-30°C) and remove it from the pouch just before use to ensure accuracy and reliable results.

Bringing to Room Temperature

Bring the Surescreen test to room temperature (15-30°C) before use to ensure optimal performance and accuracy. This step is crucial for reliable results, as temperature extremes can affect the test’s sensitivity and reaction time. Allow the test to sit at room temperature for 15-30 minutes before opening the pouch to maintain stability and consistency in testing conditions.

Removing from Pouch

Remove the Surescreen test strip from the sealed pouch just before use to prevent exposure to light and moisture. Once opened, the test should be used within one hour. Handle the strip gently to avoid touching the test area, as this could interfere with results. Ensure the test strip is undamaged and all components are intact before proceeding with the testing process.

Using the One-Step Test Strip

Dip the test strip vertically in a urine sample for 15 seconds, arrow pointing downward. Place on a flat surface and read results in 3 minutes for accuracy.

Dipping the Strip

Dip the test strip vertically into the urine sample, ensuring the arrow points downward. Submerge the absorbent tip fully for 15 seconds. Avoid splashing or spilling. After dipping, place the strip on a flat surface immediately. The control line should appear within seconds, indicating the test is working. Results will develop within 3-5 minutes. The test is CE Marked and FDA Approved for reliability.

Waiting for Results

After dipping the strip, place it on a flat surface with the result window facing up. Wait 3-5 minutes for the results. A pink control line should appear immediately, confirming the test is functioning. Two lines indicate a positive result, while one line means negative. Results are accurate and reliable, with the test being CE Marked and FDA Approved for assured quality.

Using the Midstream Test

After dipping, place the strip on a flat surface with the result window up. Wait 3-5 minutes. A pink control line confirms the test is working; Two lines indicate pregnancy, while one line means no pregnancy. Results are clear and accurate, with the test being CE Marked and FDA Approved for reliability.

Directions for Application

Bring the test to room temperature and remove it from the pouch. Aim the arrows towards your urine stream and hold it there for 15 seconds. Place the test on a flat surface with the result window up. Wait for the control line to appear, ensuring the test is working. Results are ready in 3-5 minutes, showing two lines for pregnancy or one line if not pregnant.

Reading Results

After 3-5 minutes, check the result window. Two distinct pink lines indicate a positive result, while one line means the test is negative. Ensure the control line appears, confirming the test worked. Results are accurate and easy to interpret, with clear lines indicating pregnancy status. The test’s high sensitivity ensures reliable outcomes, supported by its FDA approval and CE marking for accuracy and safety.

Interpreting Test Results

Results are indicated by colored lines in the test window. A positive result shows two lines, while a negative result displays one line. Ensure the control line appears for validity.

Positive Result

A positive result is indicated by the appearance of two distinct colored lines in the test window. The first line is the control line, ensuring the test is functioning correctly. The second line, often lighter, confirms the presence of hCG, indicating pregnancy. Results should be read within the specified time frame, typically 3-5 minutes, for accuracy.

Negative Result

A negative result is indicated by the presence of only one colored line in the test window, typically the control line. This signifies no detectable levels of hCG, suggesting the user is not pregnant. If a negative result is obtained but pregnancy is suspected, it is advisable to wait a few days and test again, especially if the menstrual period has not yet been missed.

Invalid Result

An invalid result occurs when the control line does not appear, indicating the test did not function correctly. This could be due to improper test handling, insufficient urine sample, or manufacturing defects. If an invalid result is obtained, the test should be repeated using a new test strip, ensuring all instructions are followed carefully to avoid errors.

Test Sensitivity and Accuracy

Surescreen tests detect hCG at levels as low as 20mIU/mL, ensuring early detection. With over 99% accuracy, they provide reliable results when used correctly according to instructions.

Detection Threshold

The Surescreen test detects hCG at a threshold of 20mIU/mL, ensuring early pregnancy detection. This sensitivity allows results as early as one day after a missed period, making it reliable for early confirmation. The test’s design ensures minimal false negatives when instructions are followed, providing accurate results for users seeking early pregnancy confirmation.

Accuracy Rate

The Surescreen Diagnostics Pregnancy Test boasts an impressive accuracy rate of over 99%, ensuring reliable results. Utilizing advanced immunoassay technology, the test accurately detects the presence of hCG in urine, providing clear and trustworthy outcomes. Its high sensitivity and precision make it a dependable choice for early pregnancy confirmation, supported by CE Marking and FDA approval for quality assurance.

Common FAQs

Frequently asked questions include when to take the test, how to avoid errors, and factors affecting accuracy. The test is over 99% accurate and detects hCG early.

When to Take the Test

The Surescreen Diagnostics Pregnancy Test can detect hCG as early as one day after a missed menstrual period. For optimal accuracy, test in the morning when hCG levels are highest. hCG levels rise rapidly after conception, typically exceeding 100mIU/mL by the first missed period. The test is CE Marked and FDA Approved for reliable results.

How to Avoid Errors

To ensure accurate results, follow instructions carefully. Bring the test to room temperature before use; Dip the strip correctly, avoiding contamination. Do not leave the strip in urine for more than 15 seconds. Read results within the specified time frame. Avoid re-dipping or exposing the test to excess urine to prevent errors.

Troubleshooting Common Issues

If no control line appears, the test may be expired or damaged. A faint test line could indicate low hCG levels. Always check expiry dates and follow instructions carefully to avoid errors and ensure accurate results.

No Control Line

If the control line is missing, the test is invalid. This could be due to improper testing procedure, expired test strips, or manufacturing defects. Discard the strip and repeat the test with a new one, ensuring all steps are followed correctly. Always check the expiry date before use to ensure accuracy and reliability of results.

Faint Test Line

A faint test line may appear if hCG levels are low, often due to early pregnancy or diluted urine. It still indicates a positive result, but timing and concentration can affect visibility. For accuracy, wait a few days and retest with a first-morning urine sample, as hCG levels typically rise, providing a clearer result.

Important Notes

Store the test at room temperature (15-30°C), avoiding direct sunlight and moisture. Ensure the test is used before its expiry date for accurate results.

Test Expiry

Always check the expiry date on the test packaging before use. Using an expired test may lead to inaccurate results. Store the test in a cool, dry place, avoiding direct sunlight and moisture, to maintain its effectiveness until the expiry date.

Storage Conditions

Store the Surescreen Diagnostics Pregnancy Test in a cool, dry place, away from direct sunlight and moisture. The ideal storage temperature is between 15°C and 30°C. Avoid extreme temperatures and humidity to ensure the test’s accuracy. Do not store in a freezer or leave it exposed to heat sources, as this may compromise the test’s effectiveness.

Regulatory Approvals

The Surescreen Diagnostics Pregnancy Test is both FDA-approved and CE-marked, ensuring it meets rigorous international standards for safety, quality, and performance in diagnostic testing.

CE Marking

The Surescreen Diagnostics Pregnancy Test holds a CE Mark, indicating compliance with EU health and safety standards. This certification ensures the product meets rigorous quality and performance requirements, providing users with reliable and accurate results for pregnancy detection.

FDA Approval

The Surescreen Diagnostics Pregnancy Test is FDA-approved, ensuring it meets strict U.S. regulatory standards for safety and effectiveness. This approval guarantees that the test provides accurate and reliable results, making it a trusted choice for detecting pregnancy with high sensitivity and precision.

The Surescreen Diagnostics Pregnancy Test is a reliable, FDA-approved tool offering accurate and quick results. Its user-friendly design ensures confidence in detecting pregnancy with high sensitivity and precision.

The Surescreen Diagnostics Pregnancy Test is an accurate, FDA-approved, and CE-marked diagnostic tool. It uses immunoassay technology for high sensitivity and over 99% accuracy. Available in One-Step and Midstream formats, it detects hCG levels as early as one day after a missed period. Its cost-effective design makes it a reliable choice for early pregnancy detection, ensuring quick and precise results for users.

Final Tips

Always read the instructions carefully before testing. Ensure the test is at room temperature and use the provided dropper for accurate results. Avoid contaminating the sample and interpret results within the specified time frame. If unsure, repeat the test or consult a healthcare professional. Proper storage and handling are key for test reliability and accuracy.

You Might Also Like

Leave a Reply

Back to top